Environmental

UPSS and UST Assessments

Underground petroleum storage tank assessment site

Out of sight does not mean out of risk

A buried fuel tank can operate unnoticed while a small leak spreads contaminants through soil or groundwater. UPSS and UST assessments investigate suspected or known petroleum impacts, helping you understand the extent of the issue and the environmental action the site may require.
Petroleum contamination investigation

Find petroleum impacts before they spread

Petroleum can migrate beyond the tank area through soil, groundwater and vapour pathways. Delayed investigation can expand the affected area, increase remediation costs and create risks for neighbouring properties or future development.

The assessment brings site history, tank information, field observations and targeted sampling together to determine whether a release has occurred. Where impacts are identified, the findings can guide further investigation, remediation, monitoring or regulatory reporting.

Investigation Methods

The assessment scope depends on whether the system is operating, suspected of leaking, being decommissioned or linked to a property transaction. Work may examine tanks, pipework and surrounding environmental media, with sampling targeted to likely release points and migration pathways.

System Review

Available tank, pipework, maintenance, leak-detection and incident records are reviewed to understand the system, its history and potential failure points.

Site Inspection

The site is inspected for staining, odours, damaged infrastructure, fill points, vents, drainage features and other evidence that may indicate a petroleum release.

Soil Sampling

Targeted soil samples may be collected near tanks, lines, bowsers or former infrastructure to identify petroleum hydrocarbons and define the affected area.

Groundwater Assessment

Monitoring wells and groundwater sampling may be used where a release could have reached the water table or migrated beyond the original source.

Soil Vapour

Vapour assessment may be required where volatile petroleum compounds could move through the ground and affect existing or proposed buildings.

Closure Validation

When tanks are removed or decommissioned, targeted assessment can help confirm removal of contaminated soils or whether residual contamination remains and whether further action is required.

Connected assessment across soil and groundwater

Geotesta combines contaminated-land assessment with drilling, groundwater monitoring and geotechnical capability. This connected approach helps investigation findings move into practical site decisions, while more than 35 years of specialist environmental experience supports clear communication throughout complex contamination work. Geotesta’s ability to deliver evidence-based advice through one coordinated team is why commercial organisations and government bodies across Australia trust its expertise.
Queensland Government
V/Line
Australian Geomechanics Society
Engineers Australia
NATA Technical Competence
LGCA Approved Supplier
Local Government Procurement
Transport for NSW

Frequently Asked Questions

Need clarity about a fuel storage site?

It investigates underground fuel storage infrastructure and surrounding soil, groundwater or vapour to determine whether petroleum has leaked and what environmental action may be required.

Assessment may be required after suspected leakage, during tank removal or decommissioning, before redevelopment, as part of due diligence or when requested by a regulator.

UPSS refers to the complete underground petroleum storage system, including tanks and associated pipework. UST commonly refers specifically to the underground storage tank.

Yes. Petroleum can move through soil and groundwater beyond the original source, increasing the affected area and potentially creating vapour or off-site contamination risks.

Not always. The scope depends on the system history, available records and reason for assessment. Intrusive sampling is used where evidence is needed to confirm impacts.

The analytical program is selected from the stored products, site history and suspected release. It may include petroleum or chlorinated hydrocarbons and volatile compounds relevant to fuel storage.

GET IN TOUCH

Clarify petroleum risk before it limits your site

Select Services